ASE T7 Heating, Ventilation, and Air Conditioning (HVAC) Systems practice test
Built for the ASE T7 Heating, Ventilation, and Air Conditioning (HVAC) Systems certification test in the Medium/Heavy Truck series, from the task list in ASE's 2026 study guide: high-voltage safety and electric compressors, verifying the complaint, noises, smells and component temperatures, performance tests and fault codes; gauge readings, oil and refrigerant types, R-134a and R-1234yf, leak testing, recovery, recycling, evacuation and charging, refrigerant identifiers, non-condensable gas and cylinder handling; compressor protection devices, belts, clutch air gap and compressor replacement; condensers and their air seals, receiver/driers, expansion valves and orifice tubes, cab and sleeper evaporators, the sleeper refrigerant solenoid valve, drains and the high pressure relief valve; heater output, window fogging, coolant testing and additives, hoses, caps, pumps, thermostats, bleeding, fan drives and shutters, heater coolant valves; and blower circuits, clutch coils and diodes, ECM fan control, air and electric actuators, control cables, J1939 fault codes, module setup, APU and no-idle HVAC. Every question is original, with an explanation of why the right answer is the best one.
Try the free sample Buy the full set, $12 once
The free sample is 10 questions, graded, with no sign-up. Or get All-access for $9/month: every test on the site. An account keeps your progress on every device.
What the full set includes
- 80 original four-option questions, with an explanation for every answer, 10 of them with gauge or meter readings, test results or a drawing shown as a figure
- 2 timed practice exams of 40 questions in 60 minutes, the scored length of the real test (the real one adds 10 unscored questions in the same 60 minutes)
- Each exam weighted like the real one: 6 HVAC systems diagnosis, 20 A/C system and components, 6 heating and engine cooling, 8 operating systems and controls
- Study mode (instant feedback) and exam mode (timer, graded at the end)
- Drill by topic or only your weak spots; weak spots tracked across every attempt
- 38 extra drill questions on numbered drawings of a truck A/C system with a sleeper evaporator, an orifice tube system, the engine cooling system and a relay circuit: name the part
Topics covered
- HVAC systems diagnosis, service and repair
- A/C system and component diagnosis, service and repair
- Heating and engine cooling systems diagnosis, service and repair
- Operating systems and related controls diagnosis and repair
Sample questions
Question 1
Before working on the A/C system of a battery-electric truck with an electrically driven compressor, the technician should first:
- recover the refrigerant through the high side port with the system switched on
- disconnect the 12-volt batteries, since the compressor's controls run from them
- disable the high-voltage system and verify it is de-energized
- run the compressor for a minute so the system pressures equalize first
Show the answer
C. disable the high-voltage system and verify it is de-energized. An electric compressor is driven by a motor on the high-voltage battery, hundreds of volts. The maker's procedure removes the service disconnect, waits the stated time for capacitors to discharge, and has the technician confirm zero volts with a meter rated for the job while wearing insulated gloves. Disconnecting the 12-volt batteries alone leaves the high-voltage circuit live, and nothing should be done with the system powered.
Question 2
The gauges shown are read at 1,500 rpm and 85°F on an R-134a system with an expansion valve. The sight glass shows a steady stream of bubbles. The most likely cause is:
- air trapped in the system
- a low refrigerant charge
- an expansion valve stuck open
- an overcharge of refrigerant
Show the answer
B. a low refrigerant charge. Both sides are lower than normal for 85 degrees, and bubbles in the sight glass mean vapor is reaching the drier where only liquid should be. That is a low charge, most often from a leak, which has to be found before the system is recharged. An overcharge or air raises the high side, and a stuck-open valve raises the low side.
Question 3
Heater output is poor. With the engine warm and the control at full heat, the hose into the heater core is hot and the hose out of it is much cooler. The coolant level is correct. The most likely cause is:
- a weak radiator pressure cap
- a heater core that is partly plugged
- a blend door stuck at the cold position
- a thermostat stuck open
Show the answer
B. a heater core that is partly plugged. Hot coolant is reaching the core, but it comes out much cooler, so too little of it is flowing through the core, which is what scale or debris in the tubes does. A stuck-open thermostat would make both hoses only warm. A blend door at cold does not change the hose temperatures, and a weak cap causes coolant loss and boiling, not this split.
Not affiliated with or endorsed by the National Institute for Automotive Service Excellence (ASE). ASE is a trademark of its owner. The questions here are original practice material and are not the official test or the official ASE practice tests.