ASE A7 Heating and Air Conditioning practice test
Built for the ASE A7 Heating and Air Conditioning certification test: performance testing and reading gauge pressures, leak testing, refrigerant identification, recovery, evacuation and charging with R-134a and R-1234yf, lubricants and hybrid electric compressors, engine cooling and heater systems, compressors, clutches, condensers, metering devices and the rest of the refrigeration circuit, and the electrical, vacuum and automatic temperature controls that run it all, with Technician A and Technician B questions. Every question is original, with an explanation of why the right answer is right.
Try the free sample Buy the full set, $12 once
The free sample is 10 questions, graded, with no sign-up. Or get All-access for $9/month: every test on the site. An account keeps your progress on every device.
What the full set includes
- 100 original four-option questions, with an explanation for every answer
- 2 timed practice exams of 50 questions in 75 minutes, the length of the real scored test
- Each exam weighted like the real one: 21 HVAC and engine cooling service and diagnosis, 10 refrigeration system components, 19 operating systems and controls
- 22 extra drill questions on numbered drawings of the A/C refrigerant loop and a relay circuit: name the part
- Study mode (instant feedback) and exam mode (timer, graded at the end)
- Drill by topic or only your weak spots; weak spots tracked across every attempt
Topics covered
- HVAC and engine cooling system service, diagnosis and repair
- Refrigeration system component diagnosis and repair
- HVAC operating systems and controls
Sample questions
Question 1
A technician opens the hood on a vehicle with a weak A/C complaint and finds a canister in the low-pressure line near the evaporator outlet, with no receiver/drier on the liquid line. What type of system is this most likely?
- Expansion valve system with a high-side receiver/drier
- Dual evaporator system with a rear expansion valve
- Orifice tube system with an accumulator
- Expansion valve system with a low-side accumulator
Show the answer
C. Orifice tube system with an accumulator. An accumulator on the low side with no receiver on the liquid line marks an orifice tube system. Expansion valve systems keep their receiver/drier on the high side.
Question 2
The compressor clutch will not engage. Power is good at the low pressure switch connector, but none reaches the clutch circuit past the switch. With the engine off, both gauges read very low for the ambient temperature. What does this indicate?
- The high pressure switch has failed and must be replaced
- The clutch air gap has grown too large for the coil to close
- The low pressure switch is open because the charge is gone
- The evaporator temperature control is holding the clutch off
Show the answer
C. The low pressure switch is open because the charge is gone. A low pressure switch opens the clutch circuit when static pressure is far too low, which means the system has lost most of its refrigerant. Find and fix the leak and recharge; replacing the switch or jumping it would only let the compressor run dry.
Question 3
A blower motor does not run at any speed. The fuse is good, and a test light shows power and ground at the motor connector with the switch on high. What is the most likely cause?
- A failed blower motor
- An open blower resistor block
- A failed blower relay
- A bad blower speed switch
Show the answer
A. A failed blower motor. Power and ground are arriving at the motor and it still does not turn, so the motor itself is the fault. A resistor, relay or switch problem would show up as missing power or ground at the connector.
Not affiliated with or endorsed by the National Institute for Automotive Service Excellence (ASE). ASE is a trademark of its owner. The questions here are original practice material and are not the official test or the official ASE practice tests.