ASE A6 Electrical and Electronic Systems practice test
Built for the ASE A6 Electrical/Electronic Systems certification test: general electrical diagnosis with meters, scopes, scan tools and wiring diagrams, battery and starting, charging, lighting, and body electrical from power windows to the immobilizer, with Technician A and Technician B questions. Every question is original, with an explanation of why the right answer is right.
Try the free sample Buy the full set, $12 once
The free sample is 10 questions, graded, with no sign-up. Or get All-access for $9/month: every test on the site. An account keeps your progress on every device.
What the full set includes
- 100 original four-option questions, with an explanation for every answer
- 2 timed practice exams of 50 questions in 90 minutes, the length of the real scored test
- Each exam weighted like the real one: 13 general electrical diagnosis, 9 battery and starting, 5 charging, 6 lighting, 17 body electrical
- 11 extra drill questions on a numbered drawing of a relay circuit: name the part
- Study mode (instant feedback) and exam mode (timer, graded at the end)
- Drill by topic or only your weak spots; weak spots tracked across every attempt
- Every question also in Español, shown beside the English, with an English-Español glossary (cada pregunta también en español, al lado del inglés)
Topics covered
- General electrical and electronic diagnosis
- Battery and starting systems
- Charging system
- Lighting systems
- Body electrical systems
Sample questions
Question 1
A customer says the dome light sometimes stays on after the doors are closed. What should the technician do first?
- Duplicate the concern and operate the switches
- Replace the body control module before testing anything else
- Disconnect the battery overnight and see whether it goes dead
- Replace the dome lamp bulb and its socket as a first step
Show the answer
A. Duplicate the concern and operate the switches. Verifying the concern comes first. Working the door switches, the dimmer and the delay setting shows whether it is a switch, a setting or a module fault. Parts should not be replaced before the problem has been seen and narrowed down.
Question 2
Technician A says an AGM battery should be charged with a charger that has an AGM setting or a voltage limit. Technician B says an AGM battery can usually be identified by its sealed case with no removable vent caps. Who is right?
- A only
- B only
- Both A and B
- Neither A nor B
Show the answer
C. Both A and B. AGM batteries are damaged by the higher voltages a conventional charger can reach, so the charger must limit voltage. They are sealed with no serviceable caps, and the label usually says AGM as well.
Question 3
Charging voltage at the battery is 16.2 volts at 2000 rpm. Which is the most likely cause?
- An open diode in the alternator's rectifier bridge
- A battery that is deeply discharged
- A faulty regulator or its sensing circuit
- A drive belt that is slipping on the alternator pulley
Show the answer
C. A faulty regulator or its sensing circuit. Over 15 volts is overcharging, and the regulator sets the voltage. Either the regulator has failed or the voltage it senses is lower than the battery's real voltage because of a poor sense wire or ground, so it keeps pushing.
Not affiliated with or endorsed by the National Institute for Automotive Service Excellence (ASE). ASE is a trademark of its owner. The questions here are original practice material and are not the official test or the official ASE practice tests.